A Leading South African Test and Measurement Instruments Supplier |
“For Good Measure”® |
Please contact us by phone, email or visit us at the details given above. We look forward to hearing from you. |
Product List |
T.M.I. |
Test and Measurement Instruments C.C. |
CK 1985/007464/23 |
“Tomorrow’s Instruments Today” — “For Good Measure” ® |
TMI, Established—1982 |
English, Afrikaans, Portuguese Speaking. Master/Visa Credit Cards |
Humidity / Temperature Meters |
Humidity Meters |
Part No: HT-3006HA |
Combo Humidity / Temperature & TypeK/J Thermometer, 10%-95%RH, 0-50 degC, -199 to 1300 degC, Min-Max, Data-Hold, Super Large LCD Display |
Lutron |
Part No: LM-8010 |
Combo 4 in 1 Anemometer CMM & CFM/ Humidity meter / Light Meter & Thermometer with Data-hold, Min/Max record, Fast response |
Lutron |
Part No: PHB-318 |
Combo Humidity: 10% -95% RH, Barometer : 10 - 1100hPa, Temperature Meter: 0 - 50degC. |
Lutron |
Notes on Humidity meters. Humidity measurement instruments and transducers test for absolute humidity, relative humidity, or dew point in air. The range humidity measurement instruments operate in is typically from 0 to 100% humidity. They are sometimes combined with other sensing devices such as temperature sensors. Humidity measurement instruments and sensors can sense a number of different factors. Absolute humidity, expressed as grams of water vapor per cubic meter volume of air, is a measure of the actual amount of water vapor or moisture in the air, regardless of the air's temperature. Relative humidity (RH), expressed as a percent, also measures water vapor, but relative to the temperature of the air. The dew point temperature, which provides a measure of the actual amount of water vapor in the air, is the temperature to which the air must be cooled in order for that air to be saturated and dew to form. Because of the intertwining of atmospheric measurements, humidity measurement instruments are sometimes equipped with pressure and temperature sensors as well. Three main applications for humidity measurement instruments are judging moisture in gases or air, bulk solids or powders, or else if fuels or other liquids. There are many technologies for humidity measurement instruments. Capacitive or dielectric instruments have a material that absorbs moisture, which changes its dielectric properties and enhances its capacitance. Chilled mirror technology uses a mirror that is chilled to the point that moisture starts to condense on it. This temperature is the dew point. With electrolytic technology, moisture is proportional to the current needed to electrolyze it from a desiccant. For resistivity or impedance style sensors, a material absorbs moisture, which changes its resistivity or impedance. In strain gage instruments, a material absorbs water, expands and is measured with a strain gage. Psychrometers, often called wet/dry bulbs, measure relative humidity by gauging the temperature difference between two thermometers, one wet and one dry. One critical specification for these devices is the humidity or moisture range to be measured or else the dew point range. Humidity and moisture accuracy is expressed in terms of percentage of measurement. The dew point accuracy, since this is a temperature reading, is expressed as a variance in temperature output. Outputs from humidity measurement instruments can be analog current, voltage, or frequency; digital, including computer signals; or a switch or alarm. They can have analog, digital or video type displays and can have a number of different form factors. They can be PCB-mount devices, standard sensors or transducers, or a simple gauge or indicator. They can also be various types of instruments, whether handheld, benchtop or mounted. In addition to pressure and temperature compensation, humidity measurement instruments can have a number of features to make them more useful or easier to use. These can include data logging, event triggering, self-testing, self-calibration, and battery power.
|
Humidity meters, Humidity Data loggers and Humidity / Dew Point combination meters to measure other parameters such as Light , Temperature and Pressure. |
Part No: HD-3008 |
Intelligent Humidity / Dew Point Meter, Thermometer. Uses High Precision Capacitor Thin-film sensor, not dependent on air flow. Temp Compensation. |
Lutron |
Accessories |
Adapters |
Part No: HA-702 |
Humidity Adapter. 10 to 95% RH, 1 mV DC per 1% RH. Resolution: 0,1 % RH. Output : 0– 100mV DC. Separate Probe. To be used with Multimeter or datalogger. |
Lutron |
Part No: HT-315 |
Humidity Meter, Dew Point, Temperature. Fast Response Time, Separate Probe, Min / Max Readings, Data Hold, LCD Display, RS232 Interface. |
R 2,150.00 Excl VAT |
Lutron |
Copyright © 2009—2022 Test and Measurement Instruments C.C. | All rights reserved Humidity, Dew Point and Temperature Meters |
Multipurpose Instruments |
Part No: ABH-4224 |
Combo 4-in-1 Cup Type, Air Velocity: 0.9 - 35.0 m/s, Barometer :10 - 1100hPa, Humidity: 10% -95%, Temperature Meter: 0 - 50degC. |
Part No: ABH-4225 |
Combo 4-in-1 Vane Type, Air Velocity: 0.4 - 30.0 m/s, Barometer :10 - 1100hPa, Humidity: 10% -95% RH, Temperature Meter: 0 - 50degC. |
Lutron |
Lutron |
Temperature / Humidity Controller / Monitor |
Part No: PHT-3109 |
Humidity / Temperature Controller / Monitor. Humidity: 10 to 95% RH. Temp. : 0 to 60 degC. Control and Alarm setting and Relay Outputs. |
Lutron |
Part No: SW-U801WIN |
Software, Windows 95/98, 8-channels, Data Logging Data recording using instruments with connectivity as sensors. |
Lutron |
Part No: SW-DL2005 |
Optional Data Logging Software, for HT-3009, HT-315, HT_306, HT-3015, YK-90T … downloads data from datalogging Instrument to PC for analysis in EXCEL. |
Lutron |
T + M ® |
Excess Stock to be cleared while stocks last. > Click for More... |
T + M ® |
Test our Service and Measure with our Instruments. |
Part No: LM-8000 A |
Combo 4 in 1 Anemometer / Humidity meter / Light Meter & Thermometer with Data-hold, Min/Max record Fast response. 0.4 to 35 m/s, ft/min, Km/h, Knots . |
Lutron |
Part No: HT-3007SD |
Combo Humidity / Temperature /Dew Point / Wet Bulb, TypeK/J, Thermometer, SD Card Real Time Data Logger, 10%-95%RH, 0-50 degC, -50 to 1300 degC, |
Lutron |
Part No: FLIR-MR77 |
Pinless Moisture Meter. 0-99 Relative. Moisture Depth of 19mm. METERLINK® wireless technology to integrate readings with FLIR Thermal Cameras. |
FLIR |
See also: Hygrometers |
Part No: HT-3027SD |
Humidity / Temperature /Dew Point / Wet Bulb, TypeK/J, Thermometer, SD Card Real Time Data Logger, 5%-95%RH, 0-50 degC, -50 to 1300 degC, |
Lutron |
Part No: YK-200PIR |
-10 to 300 degC, Infrared Temperature Probe for YK2001TM, C/F, Emissivity : 0.95 |
Lutron |
Wet Bulb Globe Temperature Meter. Measures WBGT, Black Globe Temperature, Humidity, Air Temperature, Wet Bulb and Dew Point. |
Humidity / Temperature Chart Recorder with Touch-Screen, Programmable. Large Hi Res Colour Screen, Replaceable Probe, Visual and Aidible Alarms, Hi/Lo Recall, |
R7300.00 excl VAT. ROE R15.00=1.USD |
Brand Names |
All brands, trade names, trade marks, and logos are the property of their respective owners. |
Ph: +27 (011) 683 4365 / 6 E-mail: sales@instrumentsgroup.co.za
Physical Address: 3 Angelica Ave, Glenvista, Johannesburg, 2091 SOUTH AFRICA
Postal Address: As Above. |
This Month’s Special |
Click Ex-Series for Spec. Also: Thermal Imagers |