A Leading South African Test and Measurement Instruments Supplier |
“For Good Measure”® |
Please contact us by phone, email or visit us at the details given above. We look forward to hearing from you. |
Product List |
T.M.I. |
Test and Measurement Instruments C.C. |
CK 1985/007464/23 |
“Tomorrow’s Instruments Today” — “For Good Measure” ® |
TMI, Established—1982 |
English, Afrikaans, Portuguese Speaking. Master/Visa Credit Cards |
Electromagnetic Field Tester |
EMF Testers |
Part No: EMF-827 |
EMF Tester. Low Frequency Electromanetic field radiation. 30 Hz to 300 Hz Ranges: 20/200/2000 micro Tesla. 200/2000/20000 milli Gauss. Separate Probe. |
R 3,100.00 Excl VAT |
Lutron |
Accessories |
Part No: EMF-824 |
EMF Adaptor, 20 Micro-Tesla, 200 milli-Gauss, Cost Effective for use with Digital Multimeter. Easy Operation. Bandwidth: 30 Hz to 300Hz. |
Lutron |
Part No: EMF-810 |
Microwave EMF Leakage Detector. Operating Frequency Range : 2.45Ghz to 50Ghz with range: 0–1.999 mW/cm2 |
R2,850.00 Excl VAT |
Lutron |
Notes on EMF Testers. EMF meters detect and monitor harmful electric, magnetic or electromagnetic fields surrounding personal or work areas. Electromagnetic fields (EMF) are invisible lines of force produced by the voltage and current which surround electrical wires or devices. These physical fields consist of two components: the electric field, which is the result of the voltage; and the magnetic field, which is the result of the current flow. One of the most common places for EMFs is near power lines; however, EMFs may also occur near electrical appliances and office equipment. In terms of human health and safety, some research indicates that elevated levels of extremely low-frequency (ELF) EMFs may cause cancer and leukemia. Consequently, electrical workers and other maintenance personnel may use EMF meters before entering a job site. EMF meters can combine magnetic, electric and radio frequency (RF) or microwave detection in a single package. Handheld devices vary in terms of measurement speed and cost, but are reliable instruments for detecting electromagnetic pollution. Specifications for EMF meters include measurement range, frequency bandwidth, percent accuracy, sampling rate, minimum resolution, number of axes, weight, dimensions, power requirements, and operating temperature. There are two measurement ranges for EMF meters: milliGaus (mG) and micro Tesla (microT). Most Gaussmeters have a measuring of range of 0.1 to 199.9 mG . Most Tesla meters have a range of 0.01 to 19.99 microT. Choices for frequency bandwidth include 30 to 300 Hz, 1 to 200 kHz, and 11 Hz at 3 db. Typically, percent accuracy is measured at 50/60 Hz. EMF meters vary in terms of features and applications. Some products have audible, adjustable alarms that sound when an electromagnetic field is encountered. Others provide datalogging capabilities with a date/time stamp for field use. Devices that have an RS-232 or universal serial bus (USB) interface are also commonly available. In terms of applications, EMF meters can be used to identify AC magnetic fields, AC electric fields, and RF radiation. Specialized EMF meters can detect hidden sources of extremely low-frequency (ELF) radiation from computers, kitchen appliances, television sets, vacuum cleaners, electric can openers, hair dryers, and power tools. Magnetometers are used to measure the direction and/or intensity of magnetic fields.
The following has been reproduced from sales literature in the Lutron range : SAFETY INSTRUCTIONS
Danger * For worker's safety, be aware that persons with electromagnetic implant ( e.g. cardiac-pacemarker ) are subject to special danger in some cases. * Particular to observe the local safety regulations of the operator of the equipment. * Before using the device, you need to know that how to Set the " alarm-limit " value.
Attention * Claims by some scientists that long term exposure to electromagnetic field may be the cause of childhood leukemia & other forms of cancer. * Complete answers to any of these and related questions are not currently available. At the present time the most common practice is to avoid excess exposure over long periods of time. * Complete answers to any of these and related " Prudent Avoidance " as stated by the Environmental Protection Agency(EPA) USA is recommended. * According to ICNIRP of reference levels to time-varying electromagnetic fields, The E-field strength levels can be seen on the following leaflet: To download please click: EMF-839 (81KB)
* ELF stands for Extremely Low Frequencies and is emitted from Power Transmission lines, substations, Home wiring and appliances.
|
Part No: EMF-839 |
3 Axis RF Electromagnetic Field Meter. 100KHz to 3 GHz 2 Probes included for precision Low & High Freq. measurements. Real Time Data Logger Built In. RS232 |
Lutron |
Part No: UPCB-02 |
Photo Coupled Isolated Interface Cable for all instruments using RS232 |
Lutron |
Part No: USB-01 |
RS232 cable with driver software for RS232 instruments. Earphone plug connects instrument RS232 output to USB terminal on computer. |
Lutron |
Copyright © 2009—2022 Test and Measurement Instruments C.C. | All rights reserved Electromagnetic Field Tester |
T + M ® |
Excess Stock to be cleared while stocks last. > Click for More... |
Part No: EMF-819 |
3 Axis Radio Frequency Electromagnetic Field Meter. 100MHz—3GHz Frequency Range. Includes EP-05H High Frequency Probe. With Data Hold and RS232 . |
Lutron |
Test our Service and Measure with our Instruments. |
Part No: TM-AM10 |
Acoustimeter, EMF Tester. Freq 200Mhz to 8Ghz. For testing Microwave signals. Readings in LCD and LED graduated indication. Peak and Average Readings. |
455.00 Pounds Sterling |
T + M |
Acousticom 2, EMF Tester. Freq 200Mhz to 8Ghz. For testing Microwave signals. LED graduated indication only. With Loudspeaker. Basic Unit. |
250.00 Pounds Sterling |
T + M |
Magnemeter Tester. Low Frequency testing of Power magnetic field levels from Substations, Power lines, Electric Railways, House Wiring, and Home appliances. |
195.00 Pounds Sterling |
T + M |
See also: Microwave Leakage |
Part No: MG-3003SD |
AC/DC MG-3003SD magnetic meter. Measures the intensity of permanent magnets and other magnets. Determines North /South Polarity. Datalogger to SD Card |
Lutron |
Part No: EMF-8218SD |
EMF Tester & Real Time Data Logger. 30Hz - 300Hz. 3 Axis RF Electromagnetic Field Meter. Sampling time: 3 to 3600 Secs. Datalogger to optional SD Card in Excel. |
Lutron |
T + M ® |
See also: Electrostatic Field Tester |
See also: Electromagnetic Field Testers |
Brand Names |
All brands, trade names, trade marks, and logos are the property of their respective owners. |
Ph: +27 (011) 683 4365 / 6 E-mail: sales@instrumentsgroup.co.za
Physical Address: 3 Angelica Ave, Glenvista, Johannesburg, 2091 SOUTH AFRICA
Postal Address: As Above. |
This Month’s Special |
Click Ex-Series for Spec. Also: Thermal Imagers |